f

422.18(B) Locating Paddle Fans in Bathrooms

New

Change Summary

  • The NEC has set boundary limitations between paddle fans and bathtub or shower.

NEC®Text

Article 422 Appliances
422.18 Ceiling-Suspended (Paddle) Fans.
(B) Location. No metal parts of ceiling-suspended (paddle) fans in bathrooms and shower spaces shall be located within a zone measured 900 mm (3 ft) horizontally and 2.5 m (8 ft) vertically from the top of the bathtub rim or shower stall threshold. This zone is all-encompassing and shall include the space directly over the tub or shower stall.

Material taken from the National Electric Code. is reprinted with permission from NFPA 70., 2023 edition. National Electrical Code®, Copyright 2022, National Fire Protection Association, Quincy, MA. All rights reserved.

Expert Analysis

A new subsection has been added to address the requirements pertaining to ceiling-suspended (paddle) fans located in bathrooms and shower spaces.

Figure 1