Change Summary
The NEC has included Garages with below grade floors, accessory buildings and boathouses in this article that relates to outdoor outlets. An exception was added for HVAC equipment with a Sept 2026 expiration date.
NEC® Text |
---|
Article 210 Branch Circuits Not Over 1000 Volts ac, 1500 Volts dc, Nominal Exception No. 1 GFCI Protection shall not be required on lighting outlets other than those covered in 210.8(C) Material taken from the National Electric Code. is reprinted with permission from NFPA 70., 2023 edition. National Electrical Code®, Copyright 2022, National Fire Protection Association, Quincy, MA. All rights reserved. |
Expert Analysis
A revision has been made to clarify that all outdoor outlets for dwellings, other than those covered in 210.8(A), Exception No. 1, including outlets installed in garages that have floors located at or below grade level, accessory building, or boathouses, are required to have GFCI protection for personnel.